{"id":9071,"date":"2024-01-18T09:47:48","date_gmt":"2024-01-18T07:47:48","guid":{"rendered":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/?page_id=9071"},"modified":"2025-01-15T14:54:02","modified_gmt":"2025-01-15T12:54:02","slug":"wamss-smart-logger","status":"publish","type":"page","link":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/","title":{"rendered":"WaMSS Smart Logger"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"9071\" class=\"elementor elementor-9071\">\n\t\t\t\t<div class=\"elementor-element elementor-element-2539a14 e-grid e-con-boxed e-con e-parent\" data-id=\"2539a14\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d4bd2de elementor-widget elementor-widget-text-editor\" data-id=\"d4bd2de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h1 style=\"text-align: center;\">WaMSS Smart Logger<\/h1>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f98a658 e-grid e-con-boxed e-con e-parent\" data-id=\"f98a658\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9522f56 elementor-widget elementor-widget-text-editor\" data-id=\"9522f56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h4 style=\"text-align: center;\">A COMPLETE, INTEGRATED LOGGING AND SCADA SOLUTION FROM ONE SUPPLIER<\/h4>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-b27536e e-flex e-con-boxed e-con e-parent\" data-id=\"b27536e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-06e55c5 e-con-full e-flex e-con e-child\" data-id=\"06e55c5\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9c88f9d elementor-widget elementor-widget-text-editor\" data-id=\"9c88f9d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h5><strong><u>SMART BATTERY POWERED DATA LOGGERS FOR FLOW, LEVEL, PRESSURE, ETC.<\/u><\/strong><\/h5><p>The <strong>FLP4 WaMSS Logger<\/strong> is a smart battery powered logger for flow, level, pressure, etc. \u00a0It is the hardware component of the WaMSS Data and Information Management System. Major applications are water conservation and water demand management solutions.<\/p><p><strong>Pulse input<\/strong> <strong>(flow)<\/strong><\/p><ul><li>Compatible with electronic or mechanical pulse sources.<\/li><li>Sensing window eliminates relay bounce errors.<\/li><li>Pulse frequency up to 15Hz.<\/li><\/ul><p><strong>Analogue input (pressure, level or other parameters)<\/strong><\/p><p>Isolated 4-20mA input ports with independent 24V loop powering options. Sleep function for power conservation.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-dfa318d e-con-full e-flex e-con e-child\" data-id=\"dfa318d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-c9a4e19 elementor-widget elementor-widget-image\" data-id=\"c9a4e19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"208\" height=\"300\" src=\"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3-208x300.jpg\" class=\"attachment-medium size-medium wp-image-13842\" alt=\"\" srcset=\"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3-208x300.jpg 208w, https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3-709x1024.jpg 709w, https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3.jpg 720w\" sizes=\"(max-width: 208px) 100vw, 208px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-835fcab e-con-full e-flex e-con e-child\" data-id=\"835fcab\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-d4ecbe1 elementor-widget elementor-widget-image\" data-id=\"d4ecbe1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"208\" height=\"300\" src=\"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide26-1-208x300.jpg\" class=\"attachment-medium size-medium wp-image-13844\" alt=\"\" srcset=\"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide26-1-208x300.jpg 208w, https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide26-1-709x1024.jpg 709w, https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide26-1.jpg 720w\" sizes=\"(max-width: 208px) 100vw, 208px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-313380d e-con-full e-flex e-con e-child\" data-id=\"313380d\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-05eaf2d elementor-widget elementor-widget-text-editor\" data-id=\"05eaf2d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Power Supply<\/strong><\/p><ul><li>Battery power: Standard high power alkaline batteries &#8211; three D cells. At least 5 years operation in standard configuration.<\/li><li>External Power Supply: 12V DC, auto changeover to battery.<\/li><\/ul><p><strong>Modem Technology:\u00a0<\/strong>Automatic switching between 4G, LTE, EDGE and GPRS<\/p><p><strong>Logger Configuration<\/strong> <strong>and diagnostics:\u00a0<\/strong>Via Bluetooth, which maintains the integrity of the enclosure.<\/p><p><strong>Logger fully configurable<\/strong> remotely via GSM link or SMS.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-a1a9aa4 e-flex e-con-boxed e-con e-parent\" data-id=\"a1a9aa4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-d355348 e-con-full e-flex e-con e-child\" data-id=\"d355348\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-09c3dcf elementor-widget elementor-widget-text-editor\" data-id=\"09c3dcf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Data logging interval<\/strong><\/p><p>Selectable from 1 minute to 24 hours.<\/p><p><strong>Data Transmission interval<\/strong><\/p><ul><li>When battery or externally powered, selectable from 1 minute to 1 week.<\/li><li>When externally powered, on-line streaming of data measurements.<\/li><\/ul><p><strong>Housing<\/strong><\/p><ul><li>Glass filled Polycarbonate enclosure \u2013 IP68 (1.2m deep, 7 days when correctly installed).<\/li><li>Glass fill for UV stability.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-34e1548 e-con-full e-flex e-con e-child\" data-id=\"34e1548\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-8e1570b elementor-widget elementor-widget-image\" data-id=\"8e1570b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"1\" height=\"1\" src=\"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide34-2-1.jpg\" class=\"attachment-medium size-medium wp-image-14176\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-5979be3 e-grid e-con-boxed e-con e-parent\" data-id=\"5979be3\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e93ac83 elementor-widget elementor-widget-text-editor\" data-id=\"e93ac83\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The complete <strong>WaMSS<\/strong> Data and Information Management System consists of this FLP Smart logger and integrated web based software.\u00a0 It delivers automatically emailed reports of flow, pressure, level daily flow totals, water balances, or other parameters, etc.<\/p><p><strong>GPS coordinates<\/strong> of logger location programmable into logger.<\/p><p><strong>Operating environment: <\/strong>-20 to 80\u00b0C.\u00a0 RH less than 90%, not condensing.<\/p><p><strong>Manufactured and supported in South Africa.<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>WaMSS Smart Logger A COMPLETE, INTEGRATED LOGGING AND SCADA SOLUTION FROM ONE SUPPLIER SMART BATTERY POWERED DATA LOGGERS FOR FLOW, LEVEL, PRESSURE, ETC. The FLP4 WaMSS Logger is a smart battery powered logger for flow, level, pressure, etc. \u00a0It is the hardware component of the WaMSS Data and Information Management System. Major applications are water [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-9071","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v24.1 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>WaMSS Smart logger - N&amp;Z Instrumentation &amp; Control<\/title>\n<meta name=\"description\" content=\"WaMSS Smart Logger with built in data transmission, sends data to the WaMSS Scada to compile and email - N&amp;Z Instrumentation &amp; Control\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"WaMSS Smart Logger\" \/>\n<meta property=\"og:description\" content=\"WaMSS Smart Logger with built in data transmission, sends data to the WaMSS Scada to compile and email - N&amp;Z Instrumentation &amp; Control\" \/>\n<meta property=\"og:url\" content=\"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/\" \/>\n<meta property=\"og:site_name\" content=\"N&amp;Z Instrumentation &amp; Control\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-15T12:54:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"720\" \/>\n\t<meta property=\"og:image:height\" content=\"1040\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wamss-smart-logger\\\/\",\"url\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wamss-smart-logger\\\/\",\"name\":\"WaMSS Smart logger - N&amp;Z Instrumentation &amp; Control\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wamss-smart-logger\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wamss-smart-logger\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wp-content\\\/uploads\\\/Slide25-3-208x300.jpg\",\"datePublished\":\"2024-01-18T07:47:48+00:00\",\"dateModified\":\"2025-01-15T12:54:02+00:00\",\"description\":\"WaMSS Smart Logger with built in data transmission, sends data to the WaMSS Scada to compile and email - N&amp;Z Instrumentation &amp; Control\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wamss-smart-logger\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wamss-smart-logger\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wamss-smart-logger\\\/#primaryimage\",\"url\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wp-content\\\/uploads\\\/Slide25-3.jpg\",\"contentUrl\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wp-content\\\/uploads\\\/Slide25-3.jpg\",\"width\":720,\"height\":1040},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/wamss-smart-logger\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"WaMSS Smart Logger\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/#website\",\"url\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/\",\"name\":\"N&amp;Z Instrumentation &amp; Control\",\"description\":\"Technology that WORKS for you!\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/jonathan.rcm-test-web.co.za\\\/nz\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"WaMSS Smart logger - N&amp;Z Instrumentation &amp; Control","description":"WaMSS Smart Logger with built in data transmission, sends data to the WaMSS Scada to compile and email - N&amp;Z Instrumentation &amp; Control","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/","og_locale":"en_US","og_type":"article","og_title":"WaMSS Smart Logger","og_description":"WaMSS Smart Logger with built in data transmission, sends data to the WaMSS Scada to compile and email - N&amp;Z Instrumentation &amp; Control","og_url":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/","og_site_name":"N&amp;Z Instrumentation &amp; Control","article_modified_time":"2025-01-15T12:54:02+00:00","og_image":[{"width":720,"height":1040,"url":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/","url":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/","name":"WaMSS Smart logger - N&amp;Z Instrumentation &amp; Control","isPartOf":{"@id":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/#website"},"primaryImageOfPage":{"@id":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/#primaryimage"},"image":{"@id":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/#primaryimage"},"thumbnailUrl":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3-208x300.jpg","datePublished":"2024-01-18T07:47:48+00:00","dateModified":"2025-01-15T12:54:02+00:00","description":"WaMSS Smart Logger with built in data transmission, sends data to the WaMSS Scada to compile and email - N&amp;Z Instrumentation &amp; Control","breadcrumb":{"@id":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/#primaryimage","url":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3.jpg","contentUrl":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-content\/uploads\/Slide25-3.jpg","width":720,"height":1040},{"@type":"BreadcrumbList","@id":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wamss-smart-logger\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/"},{"@type":"ListItem","position":2,"name":"WaMSS Smart Logger"}]},{"@type":"WebSite","@id":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/#website","url":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/","name":"N&amp;Z Instrumentation &amp; Control","description":"Technology that WORKS for you!","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-json\/wp\/v2\/pages\/9071","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-json\/wp\/v2\/comments?post=9071"}],"version-history":[{"count":35,"href":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-json\/wp\/v2\/pages\/9071\/revisions"}],"predecessor-version":[{"id":14806,"href":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-json\/wp\/v2\/pages\/9071\/revisions\/14806"}],"wp:attachment":[{"href":"https:\/\/jonathan.rcm-test-web.co.za\/nz\/wp-json\/wp\/v2\/media?parent=9071"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}